Videoswitch Mdr602a.doc Vi-R4000 Series Net Recorder User Manual Products covered by this manual Vi-R4005, Vi-R4105, Vi-R4205 Documen
Vi-R4000 Series Videoswitch Page 4 Mdr602a.doc FN/PTZ Press to enter PTZ dome mode EDIT Enter edit mode when a numeric entry is required in f
Vi-R4000 Series Videoswitch Page 5 Mdr602a.doc 1.2.2 Mouse Control The DVR can be fully controlled by a mouse and this is recommended especially
Vi-R4000 Series Videoswitch Page 6 Mdr602a.doc 1.3 Cascading Cascading is a feature that allows multiple recorders to be linked together. • Ca
Vi-R4000 Series Videoswitch Page 7 Mdr602a.doc 2 Installation
Vi-R4000 Series Videoswitch Page 8 Mdr602a.doc 2.1 Preventive and Cautionary Tips Before connecting and operating your device, please be advise
Vi-R4000 Series Videoswitch Page 9 Mdr602a.doc 2.2 Rear Panel Connections 2.2.1 Essential Connections • Connect Cameras to camera inputs 1-8
Vi-R4000 Series Videoswitch Page 10 Mdr602a.doc 2.2.3 Connecting for Cascade Operation AC POWER INPUTAC POWER INPUTAC POWER INPUT100-240VAC
Vi-R4000 Series Videoswitch Page 11 Mdr602a.doc 2.3 Replacing a Hard Drive If a hard drive needs replacing, the DVR will product an audible warn
Vi-R4000 Series Videoswitch Page 12 Mdr602a.doc 3 Commissioning
Vi-R4000 Series Videoswitch Page 13 Mdr602a.doc 3.1 Password Access If password protection is enabled, a password will need to be selected to ga
Videoswitch Mdr602a.doc
Vi-R4000 Series Videoswitch Page 14 Mdr602a.doc
Vi-R4000 Series Videoswitch Page 15 Mdr602a.doc 3.2 Default Configuration 3.2.1 System Configuration The DVR is delivered with the system config
Vi-R4000 Series Videoswitch Page 16 Mdr602a.doc 3.2.2.5 Summary of commands For all commands, press and hold the LIVE key while entering the fo
Vi-R4000 Series Videoswitch Page 17 Mdr602a.doc Auto sequencing dwell time for monitor 2 52XX XX is dwell time in seconds, 01 to 99,or 00 for de
Vi-R4000 Series Videoswitch Page 18 Mdr602a.doc 3.3 RS485 Protocols Protocol Protocol Number JVC 02 MOLYNX 03 DENNARD 04 VCL 05 SANYO 06
Vi-R4000 Series Videoswitch Page 19 Mdr602a.doc 3.4 Record Settings If you use the default configuration supplied (which may be reloaded at any
Vi-R4000 Series Videoswitch Page 20 Mdr602a.doc 3.4.3 Quality Medium quality is appropriate for most applications but this can be adjusted to ach
Vi-R4000 Series Videoswitch Page 21 Mdr602a.doc 1. Click on Copy 2. Click on Analog to select all cameras 3. Click on OK 1. Click on Apply
Vi-R4000 Series Videoswitch Page 22 Mdr602a.doc 3.4.7 Retention Period The displayed retention period is very much the worst case and assumes the
Vi-R4000 Series Videoswitch Page 23 Mdr602a.doc 3.4.8.1 16 Camera Systems 3.4.8.1.1 Retention Period for 1Tbyte, 16 cameras 2CIF 4CIF Frames pe
Vi-R4000 Series Videoswitch Mdr602a.doc Contents 1 Getting Started...1 1.1 Monitors ...
Vi-R4000 Series Videoswitch Page 24 Mdr602a.doc 3.4.8.1.3 Retention Period for 4Tbyte, 16 cameras 2CIF 4CIF Frames per second per camera Lowest
Vi-R4000 Series Videoswitch Page 25 Mdr602a.doc 3.4.8.2 12 Camera Systems 3.4.8.2.1 Retention Period for 1Tbyte, 12 cameras 2CIF 4CIF Frames per
Vi-R4000 Series Videoswitch Page 26 Mdr602a.doc 3.4.8.2.3 Retention Period for 4Tbyte, 12 cameras 2CIF 4CIF Frames per second per camera Lowest
Vi-R4000 Series Videoswitch Page 27 Mdr602a.doc 3.4.8.3 8 Camera Systems 3.4.8.3.1 Retention Period for 1Tbyte, 8 cameras 2CIF 4CIF Frames per
Vi-R4000 Series Videoswitch Page 28 Mdr602a.doc 3.4.8.3.3 Retention Period for 4Tbyte, 8 cameras 2CIF 4CIF Frames per second per camera Lowest
Vi-R4000 Series Videoswitch Page 29 Mdr602a.doc 3.4.8.4 4 Camera Systems 3.4.8.4.1 Retention Period for 1Tbyte, 4 cameras 2CIF 4CIF Frames per
Vi-R4000 Series Videoswitch Page 30 Mdr602a.doc 3.4.8.4.3 Retention Period for 4Tbyte, 4 cameras 2CIF 4CIF Frames per second per camera Lowest
Vi-R4000 Series Videoswitch Page 31 Mdr602a.doc 3.4.9 Retention Period Calculator A PC application is also available to calculate update rates
Vi-R4000 Series Videoswitch Page 32 Mdr602a.doc 3.5 Casacading 3.5.1 Vi-R4000 Recorders (address range 2) If multiple Vi-R4000 series Recorders
Vi-R4000 Series Videoswitch Page 33 Mdr602a.doc 3.5.2 Vi-R4000 Recorders (address range 1) If you have only analogue cameras and you want conseq
Vi-R4000 Series Videoswitch Mdr602a.doc 3.3.8.2.2 Retention Period for 2Tbyte, 12 cameras 25 3.3.8.2.3 Retention Period for 4Tbyte, 12 camera
Vi-R4000 Series Videoswitch Page 34 Mdr602a.doc 3.5.3 Vi405 and Vi-R4000 Recorders (address range 1) If Vi-R4000 Series Recorders are being casc
Vi-R4000 Series Videoswitch Page 35 Mdr602a.doc 3.5.3.1 Manually Set DVR Address If the DVR is being cascaded with Vi405 DVRs, you will need to
Vi-R4000 Series Videoswitch Page 36 Mdr602a.doc 3.6 Termination 3.6.1 Turn Camera Termination ON To turn the 75 Ohm camera termination ON (defa
Vi-R4000 Series Videoswitch Page 37 Mdr602a.doc 3.7 Auto-Sequencing 3.7.1 Auto-Switch Menu auto-switch is simple to set up and applies to the ma
Vi-R4000 Series Videoswitch Page 38 Mdr602a.doc For example, use these commands on the master unit (unit 1) to setup Monitor 2 auto-sequencing of
Vi-R4000 Series Videoswitch Page 39 Mdr602a.doc 3.8 Covert Cameras Covert cameras are camera that are hidden from view by are nvertheless record
Vi-R4000 Series Videoswitch Page 40 Mdr602a.doc 3.8.3 Monitor 3 3.8.3.1 Set Covert Camera To set a camera to covert enter this command: Press
Vi-R4000 Series Videoswitch Page 41 Mdr602a.doc 3.9 PTZ Control There are several methods of PTZ control: 3.9.1 Up-the-coax PTZ domes that suppo
Vi-R4000 Series Videoswitch Page 42 Mdr602a.doc 3.9.2 Connecting up Domes for RS485 Control The Vi-R4000 series DVR has four RS485 dome outputs.
Vi-R4000 Series Videoswitch Page 43 Mdr602a.doc 3.9.4 RS485 Local Control using DVR Protocols A Vi-K2, Vi-K2A or Vi-K2000 joystick keyboard can
Vi-R4000 Series Videoswitch Mdr602a.doc 3.8.4 RS485 Local Control using DVR Protocols...
Vi-R4000 Series Videoswitch Page 44 Mdr602a.doc Note: Interface commands are summarised in section 3.2.2 3.9.5 RS485 Local Control using Keybo
Vi-R4000 Series Videoswitch Page 45 Mdr602a.doc 4 User
Vi-R4000 Series Videoswitch Page 46 Mdr602a.doc 4.1 Live Viewing 4.1.1 Full screen To select full screen camera images: • Enter the camera nu
Vi-R4000 Series Videoswitch Page 47 Mdr602a.doc • Look at Camera, Record, Alarm, Network and HDD tabs and check for errors • Select Log Informati
Vi-R4000 Series Videoswitch Page 48 Mdr602a.doc 4.2 Spot Monitors 4.2.1 Using Vi-K1 remote keyboard If you plug a Vi-K1(A) keyboard into KBD2 i
Vi-R4000 Series Videoswitch Page 49 Mdr602a.doc 4.3 Play To enter playback mode Press the FIND key, or Right click mouse and select All Day Pl
Vi-R4000 Series Videoswitch Page 50 Mdr602a.doc 4.4 Video Export Video clips may be exported to a USB stick or to CDs or DVDs using the the buil
Vi-R4000 Series Videoswitch Page 51 Mdr602a.doc 4.5 Remote Viewing 4.5.1 Browser Connect to a Videwoswitch R-series Net Recorder with a browser
Vi-R4000 Series Videoswitch Page 52 Mdr602a.doc 5 Reference
Vi-R4000 Series Videoswitch Page 53 Mdr602a.doc 5.1 Menu 5.1.1 Playback 5.1.2 Recording Configuration 5.1.2.1 Quick Schedule 5.1.2.2 Advanced S
Vi-R4000 Series Videoswitch Mdr602a.doc 5.1.5 System Configuration...
Vi-R4000 Series Videoswitch Page 54 Mdr602a.doc 5.1.5.3 PTZ 5.1.5.4 Serial Settings 5.1.5.5 On Camera Settings 5.1.5.6 Exception 5.1.5.7 Display
Vi-R4000 Series Videoswitch Page 55 Mdr602a.doc 5.2 Connector Pin-outs 5.2.1 Domes Connector Type: 9-way D-type Female 126374589 Pin Function
Vi-R4000 Series Videoswitch Page 56 Mdr602a.doc 5.2.3 Keyboards Connector Type: RJ45 Female PIN1 PIN8 Pin Function 1 RS485 RX+ 2 RS485 RX- 3
Vi-R4000 Series Videoswitch Page 57 Mdr602a.doc 5.2.6 VGA Connector Type: 15-way High Density D-type Female Pin Function 1 RED 2 GREEN 3 BLUE
Vi-R4000 Series Videoswitch Page 58 Mdr602a.doc 5.2.7 Audio Connector Type: 25-way D-type Female 12314415516617718819920102122242425111213 Pin
Vi-R4000 Series Videoswitch Page 59 Mdr602a.doc 5.3 Specifications 5.3.1 Video • Video Compression H.264 • Video Input 16-ch, BNC, 1.0 Vp-p •
Vi-R4000 Series Videoswitch Page 60 Mdr602a.doc • Hard disc expansion eSATA • DVD/CD backup Built-in write (also plays back) 5.3.6 Network •
Vi-R4000 Series Videoswitch Page 61 Mdr602a.doc
Vi-R4000 Series Videoswitch Page 1 Mdr602a.doc 1 Getting Started
Vi-R4000 Series Videoswitch Page 2 Mdr602a.doc 1.1 Monitors The DVR can provide the follow output screens: • Main This is used for full-screen
Vi-R4000 Series Videoswitch Page 3 Mdr602a.doc 1.2 Control The R-series Recorders offer various methods of control. A single method or a mixture